12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems

12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems

  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems
  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems
  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems
  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems
Summary
12V Series AGM Gel Type Lead Acid Battery offers extended service life up to 8 years, superior temperature tolerance (-40°C to 60°C), and enhanced safety for telecom, UPS, power, and energy storage systems. Featuring valve-regulated sealed design, low self-discharge rate, and excellent deep-cycle performance, this maintenance-free battery ensures reliable backup power in demanding environments. Ideal for global industrial and renewable energy applications.More
Specifications
Battery chemical type:
AGM gel type
Rated voltage:
12V
Application:
Telecommunications, Power, UPS, Energy Storage Systems
  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems
  • 12V Series AGM Gel Type Lead Acid Battery Long Life & High Temperature Tolerance for Telecom Power UPS Systems

3, AGM colloidal lead-acid battery main technical characteristics

AGM colloidal lead-acid batteries are sealed lead-acid batteries, it is the general adsorption type sealed battery internal electrolyte curing, so that the performance of ordinary lead-acid batteries have increased substantially. AGM + colloidal lead-acid batteries in addition to the general characteristics of lead-acid batteries, but also has the following advantages:

3.1. Revolutionary design

※ Battery life of up to 8 years.

※ unique rapid discharge protection.

※ Colloid-type electrolyte to ensure that the battery discharge performance.

3.2 advanced production technology and technology

* Electrolyte mixed in the colloid, the battery discharge performance is more stable, also make it to the ambient temperature change width greatly improved, and has a very low self-discharge rate.

* Lead-calcium-tin + rare earth alloy to ensure the stability of the plate, and the maximum inhibition of gas generation.

※ safety valve with a unique design of security, to obtain the highest level of quality control and assurance.

3.3 high reliability protection

* Sealed design to ensure that the battery gas generation rate is minimized.

※ Flame-retardant design is selected.

* There is no restriction on the way of transport by air, rail and road according to the IATA clause.

3.4 than the adsorption-type sealed battery electrolyte 10-20%, its capacity superior to the adsorption sealed battery;

3.5 colloidal electrolyte heat capacity, heat dissipation capacity, to avoid "thermal runaway" phenomenon. And has a good low-temperature charge and discharge performance than the use of adsorption-type sealed battery wide range of -40 ~ 60 ℃ environment can be used;

3.6 Colloid electrolyte stability, no hydration, uniform distribution, there is no electrolyte layer, can be effective in slowing corrosion of positive grid, positive active material softening and negative active material sulfation;

3.7 Colloid-type electrolyte can ensure that the battery has a good charge and discharge efficiency and deep discharge performance, no early capacity attenuation phenomenon, than the average absorption of sealed battery life;

3.8 colloidal electrolyte is a colloidal three-dimensional network structure, good sealing performance, no liquid, no acid, is the ideal environmentally friendly products;

3.9 electrolyte mixed in the silica gel, the battery discharge performance is more stable, also make it to the ambient temperature change width greatly improved, and has a self-discharge rate than the general adsorption sealed lead-acid battery low, long shelf life.

4, AGM colloidal lead-acid battery use characteristics

4.1 No maintenance, the battery throughout the life of the rehydration without adding water.

4.2 High reliability, long life, special sealing structure and flame-retardant shell, in the course of the leakage of electrolyte does not produce defects, but no fire.

4.3 Self-discharge is small, 20 ℃ monthly self-discharge rate of not more than 2%.

4.4 full charge of the factory, no mobile electrolyte, transport safety.

4.5 can be used in any direction.

4.6 wide temperature range, colloidal series of batteries (-40 ℃ ~ 60 ℃).

4.7 does not require a balanced charge, due to single cell internal resistance, capacity, excellent float voltage consistency to ensure that the battery during use, without a balanced charge.

4.8 lead-acid battery with a more ideal life.

6, performance and technical indicators

6.1 battery can be -40 ℃ ~ 60 ℃, humidity less than 95%, altitude less than 3000 meters of the environment, 25 ℃ environment, float life is greater than 8 years.

6.2 The battery is tested according to the standard, 80% of the discharge depth ≥ 600 times.

6.3 Accordance with the standard battery test, sealing reaction efficiency ≥ 96%.

6.4 battery according to the standard test, the monthly self-discharge rate of ≤ 3%.

6.5 The opening pressure of the battery is 10 ~ 35Kpa, the closing valve pressure is 5 ~ 30Kpa.

6.6 The actual internal resistance of the battery and the standard deviation of the battery within the range of -10% -10%.

6.7 fully charged battery standing for 24 hours, the battery open circuit voltage difference ≤ 100mv.

6.8 The battery in the 3I10A current standard test, the connection between the battery pressure drop ≤ 8mv.

6.9 After the battery is fully charged for 90 days, its charge retention capacity is ≥90%.

7, battery application and environmental conditions

7.1 Suitable for use in telecommunications, power and UPS, and energy storage systems.

7.2 Temperature: -40 ~ +60 ℃ under normal conditions of use.

7.3 Humidity: ≤ 95%.

7.4 tolerance to earthquake capacity: the level of acceleration ≥ 0.3, vertical acceleration ≥ 0.15.

7.5 Altitude: ≤3000m

Download
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Fill out the form below to make an inquiry
Company*
Country/Region*
FirstName*
LastName*
Email*
Whatsapp/Phone*
Product Description*
Verification code*
We needs the contact information you provide to us to contact you about our products and services.
If your supplier does not respond within 24 hours, we will connect you with three to five qualified alternative suppliers.
我們使用 Cookie 來改善您的線上體驗。 繼續瀏覽本網站,即表示您同意我們使用 Cookie