Hubei,China
Brief Introduction
Automatic open flash point tester, used to determine the open flash point and ignition point of petroleum products. The instrument adopts electric ignition mode, without any flammable gas, and fully meets the method requirements of ASTMD92 (GB3536-2008) and GB267-88. Adopt ARM series high-performance microprocessor, electrically erasable memory (can store thousands of data records), color LCD and touch screen, PID self-tuning and many other latest technologies
Features
1.Strong functions. It can detect the flash point and ignition point at the same time, and print the test results. It has a clock chip inside, which automatically displays the current date, time, and power-down retention.
2.High precision. The temperature error is controlled within ±1.5℃, and the resolution is 0.1℃.
3.Good repeatability. Under the condition that the test environment is in accordance with GB3536 (ASTM D92) or GB/T 267-88, the same sample is continuously tested, and the difference in flash point value between the two is ≤ 4℃.
4.High degree of automation. It can automatically complete the test process, automatically cool down, and automatically prompt information.
The function and performance of the open flash point tester are in line with the highest level at home and abroad. It is a special instrument for replacing imported products in petroleum, electric power, chemical, commodity inspection and other industries.
working principle
The instrument is in accordance with the heating curve specified in GB/T3536-2008 (ASTMD92) and GB/T 267-88. The CPU controls the heater to heat the sample, and the color LCD display displays the status, temperature, set value, etc., when the sample temperature is close to At the flash point value, the CPU controls the electric ignition system to automatically ignite and sweep automatically. The instrument automatically locks the flash point value when a flash point occurs. At the same time, the heating is automatically stopped and the heater is air-cooled
Technical datasheet
1.Measuring range: room temperature~400℃
2.Detection type: open flash point or ignition point
3.Temperature detection: platinum resistance
4.Accuracy: ±1℃
5.Repeatability: Comply with GB3536-2008 (ASTM D92), GB/T 267-88
6.Display: color liquid crystal display
7.Information storage: 1000 measurement results can be stored
8.Ignition method: electric ignition
9.Cooling method: forced air cooling
10.Printer: dot matrix thermal printer
11.Self-check function: lift bar, sweep bar, printing, etc.
12.Work rate: ≤600VA
13.Power supply: AC 220V±11V, frequency 50Hz±2.5Hz
14.Environment temperature: 10~35℃
15.Environmental humidity: ≤90%
16.Weight: about 17kg














