| Type | Name | Parameters | Remarks |
| DC Parameters | Cell type | LFP-3.2V-280Ah | |
| Rated capacity[kwh] | 232 | ||
| Nominal voltage[V] | 832 | Voltage range 728~936 | |
| Charge-discharge rate | <0.5CP | ||
| AC Parameters(grid connected) | Rated power[kw] | 125 | |
| Grid voltage[V] | 400(-20%~10%) | ||
|
Rated current[A]
|
180
|
||
|
Rated grid frequency[Hz]
|
50/60
|
||
|
Grid frequency range [Hz]
|
45~55/55~65
|
||
|
THDi
|
<3%(rated power)
|
||
|
Power factor
|
>0.99 (rated power)
|
||
|
Power factor
adjustable range
|
-1 (leading)~l (lagging)
|
||
|
AC Parameters(off grid)
|
AC off-grid voltage[V]
|
400(-5%~5%)
|
|
|
AC off-grid frequency[Hz]
|
50/60
|
||
|
Off-grid output voltagedistortion rate
|
<1%(Linearload)
|
||
|
System Parameters
|
Cooling mode
|
PACK Liquid-cooled,PcS air-cooled
|
|
|
Fire protection system
|
Perfluoro(2-methyl-3-pentanone)+Water fire protection
|
||
|
Anti-corrosive level
|
C3
|
||
|
Ingress protection
|
IP55
|
||
|
Operatingtemperaturerange[°C]
|
-15~+45
|
||
|
Storage temperature[°C]
|
-20~+45
|
S0C@30%~50%,<6months
|
|
|
Operatinghumidity range
|
0~95%RH
|
No condensation
|
|
|
Installation mode
|
Outdoor
|
||
|
Operatingcondition
|
Max.2 charge and 2 discharge per day
|
||
|
Systemcommunication
interface
|
Ethernet/RS485
|
||
|
External system
communication protocol
|
ModbusTCP/Modbus RTU
|
||
|
Altitude[m]
|
<2000
|
>2000 derating
|
|
|
Dimension W*D*H[mm]
|
1000*1300*2300
|
||
|
Weight[kg]
|
2300+5%kg
|
||
|
Certificate
|
GB/T 36276、GB/T34131
|